Vue de la page 7
Appliance size Max. load size
6x1/1 GN 30 kg (max. 15 kg per rack)
10x1/1 GN 45 kg (max. 15 kg per rack)
20x1/1 GN 90 kg (max. 15 kg per rack)
6x2/1 GN 60 kg (max. 30 kg per rack)
10x2/1 GN 90 kg (max. 30 kg per rack)
20x2/1 GN 180 kg (max. 30 kg per rack)
Low water
The indication H2O may appear on the display
when you switch on. This means that the steam
generator is not yet filled with water. When it is full
the display goes off automatically.
• If the display is still lit, check that the water valve
is open and the strainer at the water supply
(solenoid valve) is not blocked
Ambient temperatures
If ambient temperatures drop below +5 °C, make
sure the cooking cabinet is heated to room tempe-
rature (> + 5 °C) before starting to use it.
Core temperature probe
The core temperature probe may be hot – use
oven gloves..
• Cool core temperature probe with cold water
before use
• Do not let core temperature probe hang out of
the cooking cabinet.
• Remove core temperature probe before unloa-
ding the food.
Cool Down
Use "Cool Down" function to cool the cabinet.
Caution!
During "Cool down" the fan wheel is run-
ning when the door is open!
Do not switch on "Cool down" function
unless air baffle is correctly locked
Do not touch the fan wheel.
Appliance must not be cooled with cold
water.
Hand shower (optional)
Pull hand shower out to use
Press hand shower control button to select 2 regu-
lation rates.
Hand shower retracts automatically
Make sure the hand shower is fully rewound after
use.
Caution
Hand shower and hand shower water may
be hot!
H2O